Maintenance Spo2 sensor
How to Identify Spo2 Tech Of GE Patient monitor?
How do I disinfect reusable SpO2 probes of szmedplus?
How do I stock SpO2 probes and Adapter/Extension cables?
What is the max. length of SpO2 probes?
Spo2 Sensors Difference exist
How to test Spo2 sensor?
Multi-scenario Application Of Spo2 Sensor in Medical Field
How often SpO2 reposition?
What's normal Spo2?
What's Spo2?
How to choose Spo2 sensor?
Why 10 Lead EKG Called 12 lead
GE Spo2 probe-differ module
ECG Color coding
ETCO2 Monitored Indications
Guide to put Electrode
What's ECG?
Digital&Analog spo2 sensor
Principle Of Measuring ETCO2
ow to use neonatal blood oxygen probe for blood oxygen saturation monitoring
szmedplus Tells You What You Must Know About The Electrocardiogram
Four considerations for choosing a Spo2 sensor (spo2 probe)
The Role And Principle Of Spo2 Sensor
What Is A Holter Cable
Influence Of Blood Pressure Cuff Size On Accuracy Of Blood Pressure Readings
Philips Reusable Spo2 Sensor Instructions
Introduction Of Nihon Kohden Blood Oxygen Technology
DS100A Nellcore Adult SpO2 Sensor Reusable Instructions
How To Clean A Repetitive SpO2 Probe
Which Finger Should The Blood Oxygen Sensor Be Placed On
Pros and cons of invasive blood pressure
LEMO Medical Push-Pull Connectors
How To Use And Maintain ECG Lead Wires Correctly
Can The Finger Clip Oximetry Probe Be Used in The Ear?
EKG Cable Science Knowledge
Clinical significance of disposable temperature probe

The Role And Principle Of Spo2 Sensor 

Most of the newly developed pulse oximeters use a clip sensor probe. 

When in use, the probe can be clamped on the fingertip. 
The lower wall is a photosensitive receiving device, 

which converts the red and infrared light transmitted through the finger into electrical signals. 

When the oximeter is running, the time-sharing driving circuit makes the two light-emitting diodes emit light at a certain time interval and with a relatively low duty cycle.

 Calculate the whole blood absorption rate a660 and a940, and then combine the experimental calibration coefficients A and B into the corresponding formula, 

to calculate the value of blood oxygen saturation.

And this is a continuous and non-invasive blood oxygen measurement method, 

so it will not cause any pain and side effects to people's bodies.