Maintenance Spo2 sensor
Spo2 Sensors Difference exist
How to test Spo2 sensor?
How often SpO2 reposition?
What's normal Spo2?
What's Spo2?
How to choose Spo2 sensor?
Why 10 Lead EKG Called 12 lead
GE Spo2 probe-differ module
What's ECG?
Digital&Analog spo2 sensor
Guide to put Electrode
ECG Color coding
Principle Of Measuring ETCO2
ETCO2 Monitored Indications
ow to use neonatal blood oxygen probe for blood oxygen saturation monitoring
Four considerations for choosing a Spo2 sensor (spo2 probe)
szmedplus Tells You What You Must Know About The Electrocardiogram
What Is A Holter Cable
The Role And Principle Of Spo2 Sensor
Philips Reusable Spo2 Sensor Instructions
Influence Of Blood Pressure Cuff Size On Accuracy Of Blood Pressure Readings
Introduction Of Nihon Kohden Blood Oxygen Technology
DS100A Nellcore Adult SpO2 Sensor Reusable Instructions
How To Clean A Repetitive SpO2 Probe
Which Finger Should The Blood Oxygen Sensor Be Placed On
Pros and cons of invasive blood pressure

ETCO2 Monitored Indications 

End-tidal CO2 concentration or partial pressure (ETCO2) monitoring can reflect lung ventilation, as well as pulmonary blood flow. When there is no obvious cardiopulmonary disease and the V/Q ratio is normal. ETCO2 can reflect PaCO2 (arterial blood carbon dioxide). Normal ETCO2 is 5% which is equivalent to 5KPa (38mmHg).

 

1. The safe application of anesthesia machine and ventilator.

2. Various types of respiratory insufficiency.

3. Cardiopulmonary resuscitation.

4. Severe shock.

5. Heart failure and pulmonary infarction.

6. Determine the position of the endotracheal tube in general anesthesia.

 

Clinical evaluation When using a ventilator and anesthesia, adjust the ventilation volume according to the ETCO2 measurement to keep the ETCO2 close to the preoperative level. Monitoring and its waveform can also determine whether the tracheal tube is in the airway. For those who are undergoing mechanical ventilation, such as air leakage, catheter twisting, tracheal obstruction, etc., the ETCO2 number and shape change and alarm can be immediately detected and handled in time. Continuous monitoring provides a basis for safe evacuation of mechanical ventilation. However, malignant hyperthermia, elevated body temperature, and a large amount of intravenous injection of NaHCO3 can increase CO2 production, increase ETCO2, and increase the amplitude. In shock, cardiac arrest, and pulmonary air embolism or thrombotic infarction, reduction of pulmonary blood flow can make CO2 depth drop rapidly To zero. ETCO2 also helps to judge the effectiveness of cardiopulmonary resuscitation. If ETCO2 is too low, factors such as hyperventilation should be ruled out.


Home  |  Product Catalog  |  Spo2/ECG spare part&OEM solution  |  News  |  How to buy  |  Tech Forum  |  Cata Download  |  Contact Us  |  Sitemap  |  Mobile Version
  English     简体版     繁體版
Powered by DIYTrade.com
Home Product Catalog Spo2/ECG spare part&OEM solution News How to buy Tech Forum Cata Download Contact Us
HomeContact UsSitemap