Maintenance Spo2 sensor
Spo2 Sensors Difference exist
How to test Spo2 sensor?
How often SpO2 reposition?
What's normal Spo2?
What's Spo2?
How to choose Spo2 sensor?
Why 10 Lead EKG Called 12 lead
GE Spo2 probe-differ module
What's ECG?
Digital&Analog spo2 sensor
Guide to put Electrode
ECG Color coding
Principle Of Measuring ETCO2
ETCO2 Monitored Indications
ow to use neonatal blood oxygen probe for blood oxygen saturation monitoring
Four considerations for choosing a Spo2 sensor (spo2 probe)
szmedplus Tells You What You Must Know About The Electrocardiogram
What Is A Holter Cable
The Role And Principle Of Spo2 Sensor
Philips Reusable Spo2 Sensor Instructions
Influence Of Blood Pressure Cuff Size On Accuracy Of Blood Pressure Readings
Introduction Of Nihon Kohden Blood Oxygen Technology
DS100A Nellcore Adult SpO2 Sensor Reusable Instructions
How To Clean A Repetitive SpO2 Probe
Which Finger Should The Blood Oxygen Sensor Be Placed On
Pros and cons of invasive blood pressure

Why 10 Lead EKG Called 12 lead 

Why is it called a 12 lead ECG, if it only has 10 leads?
For ECG recording, 10 electrodes are used but at each level voltage difference between two electrode points is measured and the combination the two points is termed lead. Read on for further clarification....

The term "lead" in electrocardiography causes much confusion because it is used to refer to two different things. In accordance with common parlance the word lead may be used to refer to the electrical cable attaching the electrodes to the ECG recorder. As such it may be acceptable to refer to the "left arm lead" as the electrode (and its cable) that should be attached at or near the left arm. There are usually ten of these electrodes in a standard "12-lead" ECG.

Alternatively (and some would say properly, in the context of electrocardiography) the word lead may refer to the tracing of the voltage difference between two of the electrodes and is what is actually produced by the ECG recorder. Each will have a specific name. For example "Lead I" (lead one) is the voltage between the right arm electrode and the left arm electrode, whereas "Lead II" (lead two) is the voltage between the right arm and the left leg.

In all combinations, right leg electrode does not come into play because the right leg RL electrode provides a reference potential (neutral (N) or ground.